1. bookVolumen 14 (2018): Heft 2 (December 2018)
Zeitschriftendaten
License
Format
Zeitschrift
eISSN
2255-9159
Erstveröffentlichung
31 Jan 2013
Erscheinungsweise
2 Hefte pro Jahr
Sprachen
Englisch
Uneingeschränkter Zugang

Design and Control of a STATCOM for Non-Linear Load Compensation: A Simple Approach

Online veröffentlicht: 12 Mar 2019
Volumen & Heft: Volumen 14 (2018) - Heft 2 (December 2018)
Seitenbereich: 172 - 184
Zeitschriftendaten
License
Format
Zeitschrift
eISSN
2255-9159
Erstveröffentlichung
31 Jan 2013
Erscheinungsweise
2 Hefte pro Jahr
Sprachen
Englisch

[1] S. Chattopadhyay, M. Mitra and S. Sengupta, Electric Power Quality. Springer, 2011. https://doi.org/10.1007/978-94-007-0635-410.1007/978-94-007-0635-4DOI öffnenSearch in Google Scholar

[2] Y. Hoon, M. Mohd Radzi, M. Hassan, and N. Mailah, “Control Algorithms of Shunt Active Power Filter for Harmonics Mitigation: A Review,” Energies, vol. 10, no. 12, p. 2038, Dec. 2017. https://doi.org/10.3390/en10122038.10.3390/en10122038Search in Google Scholar

[3] Y. Pal, A. Swarup and B. Singh, “A Control Strategy Based on UTT and Icosϕ Theory of Three-Phase, Four-Wire UPQC for Power Quality Improvement”, Int. J. of Eng. Sci. Tech., vol. 3, no. 1, pp. 30–40, 2011.10.4314/ijest.v3i1.67637Search in Google Scholar

[4] Y. Hoon, M. A. Mohd Radzi, M. K. Hassan, and N. F. Mailah, “Enhanced Instantaneous Power Theory With Average Algorithm for Indirect Current Controlled Three-Level Inverter-Based Shunt Active Power Filter Under Dynamic State Conditions,” Mathematical Problems in Engineering, vol. 2016, pp. 1–12, 2016. https://doi.org/10.1155/2016/968251210.1155/2016/9682512DOI öffnenSearch in Google Scholar

[5] Y. Hoon, M. Mohd Radzi, M. Hassan, and N. Mailah, “DC-Link Capacitor Voltage Regulation for Three-Phase Three-Level Inverter-Based Shunt Active Power Filter With Inverted Error Deviation Control,” Energies, vol. 9, no. 7, p. 533, Jul. 2016. https://doi.org/10.3390/en907053310.3390/en9070533DOI öffnenSearch in Google Scholar

[6] E. Hossain, M. R. Tur, S. Padmanaban, S. Ay, and I. Khan, “Analysis and Mitigation of Power Quality Issues in Distributed Generation Systems Using Custom Power Devices,” IEEE Access, vol. 6, pp. 16816–16833, 2018. https://doi.org/10.1109/ACCESS.2018.281498110.1109/ACCESS.2018.2814981DOI öffnenSearch in Google Scholar

[7] E. W. Gunther and H. Mebta, “A Survey of Distribution System Power Quality-Preliminary Results,” IEEE Transactions on Power Delivery, vol. 10, no. 1, pp. 322–329, 1995. https://doi.org/10.1109/61.36838210.1109/61.368382Search in Google Scholar

[8] B. Singh, K. Al-Haddad, and A. Chandra, “A Review of Active Filters for Power Quality Improvement,” IEEE Transactions on Industrial Electronics, vol. 46, no. 5, pp. 960–971, 1999. https://doi.org/10.1109/41.79334510.1109/41.793345Search in Google Scholar

[9] H. Akagi, “New Trends in Active Filters for Power Conditioning,” IEEE Transactions on Industry Applications, vol. 32, no. 6, pp. 1312–1322, 1996. https://doi.org/10.1109/28.55663310.1109/28.556633DOI öffnenSearch in Google Scholar

[10] D. Amoozegar, “DSTATCOM Modelling for Voltage Stability With Fuzzy Logic PI Current Controller,” International Journal of Electrical Power & Energy Systems, vol. 76, pp. 129–135, Mar. 2016. https://doi.org/10.1016/j.ijepes.2015.09.01710.1016/j.ijepes.2015.09.017Search in Google Scholar

[11] R. Singh and D. K. Singh, “Simulation of D-STATCOM for Voltage Fluctuation,” in 2012 Second International Conference on Advanced Computing & Communication Technologies, Rohtak, Haryana, 2012, pp. 225–230. https://doi.org/10.1109/ACCT.2012.10510.1109/ACCT.2012.105DOI öffnenSearch in Google Scholar

[12] P. Kanjiya, V. Khadkikar, and H. H. Zeineldin, “A Noniterative Optimized Algorithm for Shunt Active Power Filter Under Distorted and Unbalanced Supply Voltages,” IEEE Transactions on Industrial Electronics, vol. 60, no. 12, pp. 5376–5390, Dec. 2013. https://doi.org/10.1109/TIE.2012.223539410.1109/TIE.2012.2235394DOI öffnenSearch in Google Scholar

[13] M. I. M. Montero, E. R. Cadaval, and F. B. Gonzalez, “Comparison of Control Strategies for Shunt Active Power Filters in Three-Phase Four-Wire Systems,” IEEE Transactions on Power Electronics, vol. 22, no. 1, pp. 229–236, Jan. 2007. https://doi.org/10.1109/TPEL.2006.88661610.1109/TPEL.2006.886616DOI öffnenSearch in Google Scholar

[14] S. Rahmani, A. Hamadi, and K. Al-Haddad, “A Lyapunov-Function-Based Control for a Three-Phase Shunt Hybrid Active Filter,” IEEE Transactions on Industrial Electronics, vol. 59, no. 3, pp. 1418–1429, Mar. 2012. https://doi.org/10.1109/TIE.2011.216337010.1109/TIE.2011.2163370DOI öffnenSearch in Google Scholar

[15] Q.-N. Trinh and H.-H. Lee, “An Advanced Current Control Strategy for Three-Phase Shunt Active Power Filters,” IEEE Transactions on Industrial Electronics, vol. 60, no. 12, pp. 5400–5410, Dec. 2013. https://doi.org/10.1109/TIE.2012.222967710.1109/TIE.2012.2229677DOI öffnenSearch in Google Scholar

[16] E. Kabalci, “Converter and Output Filter Topologies for STATCOMs,” Power Systems, pp. 1–34, Dec. 2014. https://doi.org/10.1007/978-981-287-281-4_110.1007/978-981-287-281-4_1DOI öffnenSearch in Google Scholar

[17] Narain G. Hingorani; Laszlo Gyugyi, Understanding FACTS:Concepts and Technology of Flexible AC Transmission Systems, Piscataway, NJ, USA: Wiley-IEEE Press, 2000.Search in Google Scholar

[18] N. Mithulananthan, C. A. Canizares, J. Reeve, and G. J. Rogers, “Comparison of PSS, SVC, and STATCOM Controllers for Damping Power System Oscillations,” IEEE Transactions on Power Systems, vol. 18, no. 2, pp. 786–792, May 2003. https://doi.org/10.1109/TPWRS.2003.81118110.1109/TPWRS.2003.811181DOI öffnenSearch in Google Scholar

[19] A. Öztürk and K. Döşoğlu, “Investigation of the Control Voltage and Reactive Power in Wind Farm Load Bus by STATCOM and SVC,” in 2009 International Conference on Electrical and Electronics Engineering – ELECO 2009, Bursa, Turkey, 2009, pp. I-60–I-64.Search in Google Scholar

[20] S. T. Chavhan, C. L. Bhattar, P. V. Koli, and V. S. Rathod, “Application of STATCOM for Power Quality Improvement of Grid Integrated Wind Mill,” in 2015 IEEE 9th International Conference on Intelligent Systems and Control (ISCO), Jan. 2015. https://doi.org/10.1109/ISCO.2015.728229510.1109/ISCO.2015.7282295DOI öffnenSearch in Google Scholar

[21] S. Li, L. Xu, and T. A. Haskew, “Control of VSC-based STATCOM Using Conventional and Direct-Current Vector Control Strategies,” International Journal of Electrical Power & Energy Systems, vol. 45, no. 1, pp. 175–186, Feb. 2013. https://doi.org/10.1016/j.ijepes.2012.08.06010.1016/j.ijepes.2012.08.060DOI öffnenSearch in Google Scholar

[22] B. Singh, S. K. Dube, and S. R. Arya, “An Improved Control Algorithm of DSTATCOM for Power Quality Improvement,” International Journal of Electrical Power & Energy Systems, vol. 64, pp. 493–504, Jan. 2015. https://doi.org/10.1016/j.ijepes.2014.07.05510.1016/j.ijepes.2014.07.055DOI öffnenSearch in Google Scholar

[23] Z. Jiang, L. Yan, O. Sen, and Z. Zaitian, “Novel Hysteresis Current Controller for Active Power Filter,” in 2010 International Conference on Electrical and Control Engineering, Jun. 2010. https://doi.org/10.1109/iCECE.2010.34210.1109/iCECE.2010.342DOI öffnenSearch in Google Scholar

[24] E. F. Fuchs, M. A. S. Masoum, Eds., Power Quality in Power Systems and Electrical Machines. London, UK: Elsevier Academic Press, 2008. https://doi.org/10.1016/B978-0-12-369536-9.X5001-310.1016/B978-0-12-369536-9.X5001-3DOI öffnenSearch in Google Scholar

[25] A. Ghosh, G. Ledwich, Power Quality Enhancement using Custom Power Devices, Springer, 2009. https://www.springer.com/gp/book/9781402071805Search in Google Scholar

[26] T. Tanaka, E. Hiraki, K. Ueda, K. Sato, and S. Fukuma, “A Novel Detection Method of Active and Reactive Currents in Single-Phase Circuits Using the Correlation and Cross-Correlation Coefficients and Its Applications,” IEEE Transactions on Power Delivery, vol. 22, no. 4, pp. 2450–2456, Oct. 2007. https://doi.org/10.1109/TPWRD.2007.90535910.1109/TPWRD.2007.905359DOI öffnenSearch in Google Scholar

[27] S. Sharma and B. Singh, “An Enhanced Phase Locked Loop Technique for Voltage and Frequency Control of Stand-Alone Wind Energy Conversion System,” in India International Conference on Power Electronics 2010 (IICPE2010), New Delhi, 2011, pp. 1–6. https://doi.org/10.1109/IICPE.2011.572806410.1109/IICPE.2011.5728064DOI öffnenSearch in Google Scholar

[28] K. Ilango, A. Bhargav, A. Trivikram, P. S. Kavya, G. Mounika, and M. G. Nair, “Power Quality Improvement Using STATCOM with Renewable Energy Sources,” in 2012 IEEE 5th India International Conference on Power Electronics (IICPE), Dec. 2012. https://doi.org/10.1109/IICPE.2012.645046210.1109/IICPE.2012.6450462DOI öffnenSearch in Google Scholar

[29] A. H. M. A. Rahim, S. A. Al-Baiyat, and H. M. Al-Maghrabi, “Robust Damping Controller Design for a Static Compensator,” in IEE Proceedings – Generation, Transmission and Distribution, vol. 149, no. 4, p. 491, 2002. https://doi.org/10.1049/ip-gtd:2002034410.1049/ip-gtd:20020344Search in Google Scholar

[30] A. H. M. A. Rahim and M. F. Kandlawala, “Robust STATCOM Voltage Controller Design Using Loop-Shaping Technique,” Electric Power Systems Research, vol. 68, no. 1, pp. 61–74, Jan. 2004. https://doi.org/10.1016/S0378-7796(03)00153-610.1016/S0378-7796(03)00153-6DOI öffnenSearch in Google Scholar

[31] B. Zigmund, A. Terlizzi, X.T. Garcia, R. Pavlanin and L. Salvatore “Experimental Evaluation of PI Tuning Techniques for Field Oriented Control of Permanent Magnet Synchronous Motors”, Advances in Electrical and Electronic Engineering, pp. 114–119. [Online] Available: http://advances.utc.sk/index.php/AEEE/article/view/234/212Search in Google Scholar

[32] R.-J. Wai, J.-D. Lee, and K.-L. Chuang, “Real-Time PID Control Strategy for Maglev Transportation System via Particle Swarm Optimization,” IEEE Transactions on Industrial Electronics, vol. 58, no. 2, pp. 629–646, Feb. 2011. https://doi.org/10.1109/TIE.2010.204600410.1109/TIE.2010.2046004DOI öffnenSearch in Google Scholar

[33] M. J. Neath, A. K. Swain, U. K. Madawala, and D. J. Thrimawithana, “An Optimal PID Controller for a Bidirectional Inductive Power Transfer System Using Multiobjective Genetic Algorithm,” IEEE Transactions on Power Electronics, vol. 29, no. 3, pp. 1523–1531, Mar. 2014. https://doi.org/10.1109/TPEL.2013.226295310.1109/TPEL.2013.2262953DOI öffnenSearch in Google Scholar

[34] A. O’Dwyer, Handbook of PI and PID Controller Tuning Rules, 2nd ed. London, UK: Imperial College Press, 2006. https://doi.org/10.1142/p42410.1142/p424DOI öffnenSearch in Google Scholar

[35] S. M. Tripathi, A. N. Tiwari and D. Singh, “Optimum Design of Proportional-Integral Controllers in Grid-Integrated PMSG-Based Wind Energy Conversion System,” Int. Trans. Electr. Energy Syst., pp. 1006–1031, 2016. https://doi.org/10.1002/etep.212010.1002/etep.2120DOI öffnenSearch in Google Scholar

[36] K. G. Papadopoulos and N. I. Margaris, “Extending the Symmetrical Optimum Criterion to the Design of PID Type-p Control Loops,” Journal of Process Control, vol. 22, no. 1, pp. 11–25, Jan. 2012. https://doi.org/10.1016/j.jprocont.2011.10.01410.1016/j.jprocont.2011.10.014DOI öffnenSearch in Google Scholar

[37] K. J. Aström and T. Hägglund, PID Controllers: Theory, Design and Tuning, 2nd ed. Research Triangle Park NC, USA: Instr. Soc. Amer., 1995.Search in Google Scholar

[38] J. W. Umland and M. Safiuddin, “Magnitude and Symmetric Optimum Criterion for the Design of Linear Control Systems: What Is It and How Does It Compare With the Others?,” IEEE Transactions on Industry Applications, vol. 26, no. 3, pp. 489–497, 1990. https://doi.org/10.1109/28.5596710.1109/28.55967DOI öffnenSearch in Google Scholar

[39] M. Adel, S. Zaid, and O. Mahgoub, “Improved Active Power Filter Performance Based on an Indirect Current Control Technique,” Journal of Power Electronics, vol. 11, no. 6, pp. 931–937, Nov. 2011. https://doi.org/10.6113/JPE.2011.11.6.93110.6113/JPE.2011.11.6.931DOI öffnenSearch in Google Scholar

[40] G.-C. Hsieh and J. C. Hung, “Phase-Locked Loop Techniques. A Survey,” IEEE Transactions on Industrial Electronics, vol. 43, no. 6, pp. 609–615, Dec. 1996. https://doi.org/10.1109/41.54454710.1109/41.544547DOI öffnenSearch in Google Scholar

[41] B. Singh and S. Arya, “Design and Control of a DSTATCOM for Power Quality Improvement Using Cross Correlation Function Approach,” International Journal of Engineering, Science and Technology, vol. 4, no. 1, Dec. 2012.10.4314/ijest.v4i1.9SSearch in Google Scholar

[42] L. T. Moran, P. D. Ziogas, and G. Joos, “Analysis and Design of a Three-Phase Synchronous Solid-State VAr Compensator,” IEEE Transactions on Industry Applications, vol. 25, no. 4, pp. 598–608, 1989. https://doi.org/10.1109/28.3123610.1109/28.31236DOI öffnenSearch in Google Scholar

[43] M. Singh, V. Khadkikar, and A. Chandra, “Grid Synchronisation with Harmonics and Reactive Power Compensation Capability of a Permanent Magnet Synchronous Generator-Based Variable Speed Wind Energy Conversion System,” IET Power Electronics, vol. 4, no. 1, p. 122, 2011. https://doi.org/10.1049/iet-pel.2009.013210.1049/iet-pel.2009.0132Search in Google Scholar

[44] H.-B. Shin, “New Antiwindup PI Controller for Variable-Speed Motor Drives,” IEEE Transactions on Industrial Electronics, vol. 45, no. 3, pp. 445–450, Jun. 1998. https://doi.org/10.1109/41.67900210.1109/41.679002DOI öffnenSearch in Google Scholar

[45] Y. Hoon, M. A. M. Radzi, M. K. Hassan, N. F. Mailah, and N. I. A. Wahab, “A Simplified Synchronous Reference Frame for Indirect Current Controlled Three-Level Inverter-Based Shunt Active Power Filters,” Journal of Power Electronics, vol. 16, no. 5, pp. 1964–1980, Sep. 2016. https://doi.org/10.6113/JPE.2016.16.5.196410.6113/JPE.2016.16.5.1964DOI öffnenSearch in Google Scholar

[46] J. H. Marks and T. C. Green, “Predictive Transient-Following Control of Shunt and Series Active Power Filters,” IEEE Transactions on Power Electronics, vol. 17, no. 4, pp. 574–584, Jul. 2002. https://doi.org/10.1109/TPEL.2002.80097010.1109/TPEL.2002.800970DOI öffnenSearch in Google Scholar

[47] M. Altin, O. Goksu, R. Teodorescu, P. Rodriguez, B.-B. Jensen, and L. Helle, “Overview of Recent Grid Codes for Wind Power Integration,” in 2010 12th International Conference on Optimization of Electrical and Electronic Equipment, May 2010. https://doi.org/10.1109/OPTIM.2010.551052110.1109/OPTIM.2010.5510521DOI öffnenSearch in Google Scholar

[48] M. Tsili and S. Papathanassiou, “A Review of Grid Code Technical Requirements for Wind Farms,” IET Renewable Power Generation, vol. 3, no. 3, p. 308, 2009. https://doi.org/10.1049/iet-rpg.2008.007010.1049/iet-rpg.2008.0070DOI öffnenSearch in Google Scholar

[49] E.ON Netz GmbH, Bayreuth, Grid Code–High and Extra High Voltage. Germany: April, 2006. [Online]. Available: https://www.nerc.com/comm/PC/Integration%20of%20Variable%20Generation%20Task%20Force%20IVGT/Sub%20Teams/Interconnection/German_EON_Grid_Code.pdfSearch in Google Scholar

[50] Nordel, Nordic Grid Code, January 2007. [Online]. Available: https://www.entsoe.eu/fileadmin/user_upload/_library/publications/nordic/planning/070115_entsoe_nordic_NordicGridCode.pdfSearch in Google Scholar

[51] Wind Turbines Connected to Grids with Voltages Below 100 kV, Regulation TF 3.2.6, Energinet, Denmark, May 2004. [Online]. Available: https://en.energinet.dk/-/media/1196EE254B854D21AD88B2DC813BFEA9.pdf?la=en&hash=ACF6DBC39FEF7340E206E48BE4845941519CAE97Search in Google Scholar

Empfohlene Artikel von Trend MD

Planen Sie Ihre Fernkonferenz mit Scienceendo