Analogous Mode Implementation of State Space Based Control of Buck Converter
und
01. Feb. 2023
Über diesen Artikel
Online veröffentlicht: 01. Feb. 2023
Seitenbereich: 91 - 104
Eingereicht: 13. Aug. 2022
Akzeptiert: 13. Dez. 2022
DOI: https://doi.org/10.2478/bipie-2022-0006
Schlüsselwörter
© 2022 Diana-Elena Cucoș et al., published by Sciendo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
The new requirements for point-of-load converters include the dynamic behavior, leading to the need for improvements in the control system for the conventional buck converter. Usually, the regulator design, in order to secure stability at parameter or mode variation, aims a zero steady-state error and a phase margin over 60 degrees. The design based on Venable’s K-factor method (Venable, 1983) helps achieve this topic. A more modern control design method based on State Space is used progressively on digital platforms. This paper extends the merits of the State Space based design procedure with an analogous mode implementation.