Ahmad A., Maslehuddin M., Al-Hadhrami L.M., In situ measurement of thermal transmittance and thermal resistance of hollow reinforced precast concrete walls, Energ. Buildings 84, 132-141 (2014).
]Search in Google Scholar
[
Albatici R., Tonelli A.M., Infrared thermovision technique for the assessment of thermal transmittance value of opaque building elements on site, Energ. Buildings 42, 2177-2183 (2010).
]Search in Google Scholar
[
Asdrubali F., Baldinelli G., Bianchi F., Vera Collado B., Tanner Ch., A quantitative methodology to evaluate thermal bridges in buildings, Appl. Energy. 97, 365-373 (2012).
]Search in Google Scholar
[
Barreira E., de Freitas V.P., Evaluation of building materials using infrared thermography, Constr. Build Mater. 21, 218-224 (2007).
]Search in Google Scholar
[
Ficco G., Iannetta F., Ianniello E., Romano d’Ambrosio F., Dell’Isola M., U-value in situ measurement for energy diagnosis of existing buildings, Energ. Buildings 104, 108-121 (2015).
]Search in Google Scholar
[
Fokaides P.A., Kalogirou S.A., Application of infrared thermography for the determination of the overall heat transfer coefficient (U-Value) in building envelopes, Appl. Energy. 88, 4358-4365 (2011).
]Search in Google Scholar
[
Gaspar K., Casals M., Gangolells M., In situ measurement of façades with a low U-value: Avoiding deviations, Energ. Buildings 170, 61-73 (2018).
]Search in Google Scholar
[
Lehmann B., Ghazi Wakili K., Frank Th., Vera Collado B., Tanner Ch., Effects of individual climatic parameters on the infrared thermography of buildings, Appl. Energy. 110, 29-43 (2013).
]Search in Google Scholar
[
Litti G., Khoshdel S., Audenaert A., Braet J., Hygrothermal performance evaluation of traditional brick masonry in historic buildings, Energ. Buildings 105, 393-411 (2015).
]Search in Google Scholar
[
Meng X., Gao Y., Wang Y., Yan B., Zhang W., Long E., Feasibility experiment on the simple hot box-heat flow meter method and the optimization based on simulation reproduction, Appl. Therm. Eng. 83, 48-56 (2015).
]Search in Google Scholar
[
Meng X., Yan B., Gao Y., Wang J., Zhang W., Long E., Factors affecting the in situ measurement accuracy of the wall heat transfer coefficient using the heat flow meter method, Energ. Buildings 86, 754-756 (2015).
]Search in Google Scholar
[
Rasooli A., Itard L., Ferreira C.I., A response factor-based method for the rapid in-situ determination of wall’s thermal resistance in existing buildings, Energ. Buildings 119, 51-61 (2016).
]Search in Google Scholar
[
Teni M., Krstic H., Kosinski P., Review and comparison of current experimental approaches for in-situ measurements of building walls thermal transmittance, Energ. Buildings 203, 109417 (2019).
]Search in Google Scholar
[
*** ISO 9869-1:2014, “Thermal insulation – building elements – in-situ measurement of thermal resistance and thermal transmittance – Part 1: heat flow meter method”.
]Search in Google Scholar
[
*** ISO 9869-2:2018 “Thermal insulation – Building elements – In-situ measurement of thermal resistance and thermal transmittance – Part 2: Infrared method for frame structure dwelling”.
]Search in Google Scholar