Uneingeschränkter Zugang

Comparative evaluation of shear bond strength and debonding properties of GC Ortho Connect composite and Transbond XT composite


Zitieren

Descriptive and analytical statistics of shear bond strength (MPa) of the three groups (n=20).

Group Composite Mean Std. deviation Minimum Maximum Tukey’s Test
I Transbond XT with primer 12.66 3.3 7.18 18.21 A*
II GC Ortho Connect 15.50 3.25 10.82 20.78 B
III Transbond XT without primer 11.18 4.94 5.50 24.28 A

Experimental groups (n=20).

Groups Etchant Primer Composite resin
I 37% phosphoric acid Transbond XT Transbond XT
II 37% phosphoric acid GC Ortho Connect
III 37% phosphoric acid Transbond XT

Frequency distribution and percentage of the adhesive ARI scores in the three groups(n=20).

ARI score*
Groups Composite 0 1 2 3 Mann–Whitney U Test
I Transbond XT with primer 9 (45%) 6 (30%) 4 (20%) 1 (5%) A**
II GC Ortho Connect 5 (25%) 2 (10%) 8 (40%) 5 (25%) B
III Transbond XT without primer 11 (55%) 4 (20%) 4 (20%) 1 (5%) A
eISSN:
2207-7480
Sprache:
Englisch
Zeitrahmen der Veröffentlichung:
Volume Open
Fachgebiete der Zeitschrift: