Background

Increased concentrations of nickel ions may be released into saliva from recycled NiTi archwires.

Aim

To compare the nickel ion concentrations released from recycled NiTi wires after sterilisation by either dry heat or steam autoclave.

Methods

Eighty preformed NiTi wires were assigned to four equal groups. In Groups 1, 2 and 3 the archwires were used intra-orally for 4 weeks. The Group 4 archwires were not used. Group 1 archwires were sterilised by dry heat, the Group 2 archwires were sterilised by steam autoclave, the Group 3 archwires were not sterilised and the Group 4 archwires were as-received. A 2 cm length, cut from each archwire, was immersed in artificial saliva for 4 weeks and the nickel ion concentrations in the artificial saliva measured with an atomic absorption spectrophotometer.

Results

There were no significant differences in the nickel ion concentrations released into the artificial saliva by each group of archwires (p = 0.467).

Conclusion

Sterilisation of used NiTi wires by either dry heat and steam autoclave does not affect the concentrations of nickel ions released into artificial saliva.