Uneingeschränkter Zugang

The Influence of Pulsating Tensile Stress on Residual Magnetic Field of P91 Steel Samples


Zitieren

Measurements of Residual Magnetic Field RMF (the tangential component parallel to the load direction) were taken on the surface of P91 steel plate samples (X10CrMoVNb9-1) subjected to periodic pulsating tensile cyclic loads with the use of flux-gate and magneto impedance sensors, and preliminary measurement results are compiled and analyzed. The study investigates how the microstructure and load cycle parameters affect the RMF changes due to stress variations. Each combination of parameters: microstructure and load cycle corresponds to the characteristic variability pattern of magnetization and its maximum and minimum values.

eISSN:
2083-4799
Sprache:
Englisch
Zeitrahmen der Veröffentlichung:
4 Hefte pro Jahr
Fachgebiete der Zeitschrift:
Materialwissenschaft, Funktionelle und Intelligente Materialien