Login
Registrieren
Passwort zurücksetzen
Veröffentlichen & Verteilen
Verlagslösungen
Vertriebslösungen
Themen
Allgemein
Altertumswissenschaften
Architektur und Design
Bibliotheks- und Informationswissenschaft, Buchwissenschaft
Biologie
Chemie
Geowissenschaften
Geschichte
Industrielle Chemie
Informatik
Jüdische Studien
Kulturwissenschaften
Kunst
Linguistik und Semiotik
Literaturwissenschaft
Materialwissenschaft
Mathematik
Medizin
Musik
Pharmazie
Philosophie
Physik
Rechtswissenschaften
Sozialwissenschaften
Sport und Freizeit
Technik
Theologie und Religion
Wirtschaftswissenschaften
Veröffentlichungen
Zeitschriften
Bücher
Konferenzberichte
Verlage
Blog
Kontakt
Suche
EUR
USD
GBP
Deutsch
English
Deutsch
Polski
Español
Français
Italiano
Warenkorb
Home
Zeitschriften
Architecture, Civil Engineering, Environment
Band 15 (2022): Heft 4 (December 2022)
Uneingeschränkter Zugang
The Criterion of Access to the Sky View in Residential Environment Architectural Designing
Zdzisław Pelczarski
Zdzisław Pelczarski
| 03. Feb. 2023
Architecture, Civil Engineering, Environment
Band 15 (2022): Heft 4 (December 2022)
Über diesen Artikel
Vorheriger Artikel
Nächster Artikel
Zusammenfassung
Artikel
Figuren und Tabellen
Referenzen
Autoren
Artikel in dieser Ausgabe
Vorschau
PDF
Zitieren
Teilen
Online veröffentlicht:
03. Feb. 2023
Seitenbereich:
43 - 61
Eingereicht:
13. Juli 2022
Akzeptiert:
29. Nov. 2022
DOI:
https://doi.org/10.2478/acee-2022-0037
Schlüsselwörter
Graphical methods of analysis
,
Sight line
,
Sky view entry angle
,
View through the window
,
Viewing angle
,
Visual perception
,
Residential environment architectural designing
© 2022 Zdzisław Pelczarski, published by Sciendo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Figure 1
Chosen historical methods of establishing building-to-building distances in the context of daylighting and access to the sky view A. More than 200 years ago, Prussian land law clearly regulated the distances between adjacent residential buildings, requiring that the sky was visible from the ground floor windows of each of these buildings. Source: author, based on [30].B. New regulations concerning the buildings and streets of times of the Haussmannian transformation of Paris (1853–1870) – the facades couldn't exceed 20 meters in height in streets 20 meters in width and the roofs had to be diagonal at 45 degrees. Source: author, based on [31].C. The principle of opening angle 4° and incidence angle 27°, as a method of determining the daylight illumination of living quarters according to DIN. Source: author, based on [32]
Figure 2
Basis of the Relative Retinal Image Method. Source: author, based on [40b]
Figure 3
Dependence of the external environment image size and scope in the window opening frame on the observer distance. Source: author
Figure 4
The issue of access to the sky view – definition of general theoretical basis of the analysis. Source: author
Figure 5
The research model based on the application of the relative retinal image method. Source: author, based on [40a]
Figure 6
Analysis of the impact of minimal sky view entry angle on the distance between buildings. Source: author
Figure 7
Analysis of the height of the relative retinal images of the sky for eye points EP (1–7) of building A. Dependence of the size of the sky view entry angles on the position of the EP eye points on individual storeys of the building under study. Comparison of the extreme sizes of the retinal sky images in the window frame for the eye points EP1 and EP6, (Detail “a”). Source: author