Erfordert Authentifizierung

Development and validation of a fluorescent microsphere immunoassay for anti-IgA


Zitieren

Anti-IgA may cause anaphylactic transfusion reactions in IgA-deficient individuals. Testing for IgG anti-IgA is useful to identify persons at risk. This report describes an immunoassay for anti-IgA that uses polyclonal IgA coupled to fluorescent microspheres as an immunosorbent. Anti-IgA is detected by phycoerythrin-labeled anti-IgG. The assay is calibrated in arbitrary units by use of a serum that contains anti-IgA. Dose-response studies with sera that contain anti-IgA showed positive responses at dilutions up to 32-fold greater than the dilution used to test patients’ samples. Inhibition studies with purified IgA and IgA-deficient serum showed no inhibition with IgA-deficient serum and complete inhibition with soluble IgA. Clinical tests performed in more than 90 assays had a CV of 13.6 percent for measurements of an internal positive control. The fluorescent immunoassay method is rapid, reproducible, and sensitive to low concentrations of IgG anti-IgA. Immunohematology2009;25:24–28.

eISSN:
1930-3955
Sprache:
Englisch
Zeitrahmen der Veröffentlichung:
4 Hefte pro Jahr
Fachgebiete der Zeitschrift:
Medizin, Klinische Medizin, Laboratoriumsmedizin