Thermal Improvement in Residential Buildings in View of the Indoor Air Quality – Case Study for Polish Dwelling


Zitieren

Figure 1.

The variability of monthly mean temperature
The variability of monthly mean temperature

Figure 2.

The variability of monthly maximum of relative humidity
The variability of monthly maximum of relative humidity

Figure 3.

The variability of monthly maximum of CO2 concentration
The variability of monthly maximum of CO2 concentration

Figure 4.

The variability of the average monthly CO2 concentration
The variability of the average monthly CO2 concentration

Figure 5.

Measurement by Blower Door
Measurement by Blower Door

Figure 6.

Elimination of leakages of dwelling
Elimination of leakages of dwelling

Figure 7.

Measurement of air flow in exhaust opening
Measurement of air flow in exhaust opening

Figure 8.

Measured and simulated exhaust air flow
Measured and simulated exhaust air flow

Figure 9.

Measured and predicted mean air flow rate in the flat
Measured and predicted mean air flow rate in the flat

Figure 10.

Air flows in tested dwelling
Air flows in tested dwelling

Figure 11.

The air exchange rate according to different opening level of the air inlets
The air exchange rate according to different opening level of the air inlets

The required and measured exhaust air flow

Room The required exhaust air flow, m3/h The measured exhaust air flow, m3/h
Kitchen 70 9.90
Bathroom 50 15.24
Toilet 30 18.49

Room characteristics

No of room Kind of room Area Volume Characteristic
m2 m3
01 room 1 11.10 27.75 Student’s living-room and bedroom. The door is often closed. Heated in wintertime.
02 living-room 2 17.40 43.50 Living-room and dining room. The room is empty at night. In winter time heating isn’t required all the time.
03 bathroom 3 3.20 8.00 Occupants take a bath in the mornings and evenings. Clothes are dried very often.
04 kitchen 4 5.60 14.00 Room without door, meals are prepared three times a day.
05 room 5 10.50 26.25 Student’s living-room and bedroom. Heated in wintertime.
06 room 6 8.00 20.00 Bedroom close to the staircase. Occasionally heated in wintertime.
07 hall 7 15.20 38.00
71.0 177.5

Results of airtightness measurement.

n50, h-1 V50, m3/h C, m3/(h.Pan) a, m3/(m.h.Pan)
Underpressure 1.14 195 15.15 0.32
Overpressure 1.18 202 14.20 0.30

Air change rate according to PN-EN 12831 standard

Building Airtightness requirement at 50 Pa pressure n50, h -1
high airtightness medium airtightness low airtightness
Single family buildings <4 4÷10 >10
Multifamily dwelling houses <2 2÷5 >5