TIMBER VOLUME INROOF TRUSSES BY MODULE 2 | ||||||
---|---|---|---|---|---|---|
Type of module: full-full-full (module length – 3m) | Type of module: incomplete-full-incomplete (module length – 3 m) | |||||
Number of units | Roof truss volume | Module volume | Number of units | Roof truss volume | Module volume | |
Full roof framings of type 1A | 3 trusses | 2.01 | 6.03 | 1 truss | 2.01 | 2.01 |
Incomplete roof framings of type 1B | - | - | - | 2 trusses | 1.28 | 2.56 |
Purlins connecting trusses spatially (8pcs) | 3m | 0.34 | 1.02 | 3 m | 0.34 | 1.02 |
TOTAL MODULE VOLUME | 14.31 m3 | TOTAL MODULE VOLUME | 10.21 m3 | |||
PERCENTAGE OF TIMBER USED | ||||||
module consisting of three full roof framings | 100.0% | module consisting of one full and two incomplete roof framings | 79.3% |
TIMBER VOLUME IN ROOF TRUSSES BY MODULE 1 | ||||||
---|---|---|---|---|---|---|
Type of module: full-full-full (module length – 3 m) | Type of module: incomplete-full-incomplete (module length – 3 m) | |||||
Number of units | Roof truss volume | Module volume | Number of units | Roof truss volume | Module volume | |
Full roof framings of type 1A | 3 trusses | 4.39 | 13.17 | 1 truss | 4.39 | 4.39 |
Incomplete roof framings of type 1B | - | - | - | 2 trusses | 2.34 | 4.68 |
Purlins connecting trusses spatially (7pcs) | 3 m | 0.38 | 1.14 | 3m | 0.38 | 1.14 |
TOTAL MODULE VOLUME | 14.31 m3 | TOTAL MODULE VOLUME | 10.21 m3 | |||
PERCENTAGE OF TIMBER USED | ||||||
module consisting of three full roof framings | 100.0% | module consisting of one full and two incomplete roof framings | 71.3% |