Uneingeschränkter Zugang

Study of Harmonic Detection Methods under Non-Ideal Conditions in Ship Power Network


Zitieren

1. Akagi H., Kanazawa Y., Nabae A., Instantaneous reactive power compensators comprising switching devices without energy storage components, IEEE Transactions on Industry Application 20 (3) (1984) 625-63010.1109/TIA.1984.4504460Search in Google Scholar

2. Ding Ju-Xia, Zhang Xiu-Feng. A harmonics-detection method without PLL and based on average theory in single-phase circuit [J]. Power System Protection and Control, 2010, 38(13): 26-30Search in Google Scholar

3. Dong Tian-Bing, Cheng Han-Xiang, He Man-run. Time delay analyzing and the setting about the frequency compensation of active power Filter [J]. Electric Drive, 2011, 41(2): 24-27Search in Google Scholar

4. EN Standard 50160. Voltage characteristics of electricity supplied by public distribution systemsSearch in Google Scholar

5. IEC 61000-4-7:2007 General Guide on Harmonics and Interharmonics Measurements for Power Supply Systems and Equipment Connected TheretoSearch in Google Scholar

6. Jiang You-Hua, Cao Yi-long, Tang Zhong. Design and application of active power filter based on average arithmetic [J]. Power Electronics, 2010, 44(2): 42-43Search in Google Scholar

7. Lu Zhen, Liang Guo-Lu, Lu Yu. Improved ip-iq harmonic detection method and simulation [J]. Power Electronics, 2012, 46(5): 81-83Search in Google Scholar

8. Meng Jun-Xia, Zhou Zi-Guan, Li Guang-Hui. Detection of Distorted Current Based on ip-iq Method and Its Physical Realization [J]. Power System Technology, 2012, 36(5): 125-131Search in Google Scholar

9. Mindykowski J., Xu X., Tarasiuk T., A new concept of harmonic current detection for shunt active power filters control, Measurement 46 (2013) 4334-434110.1016/j.measurement.2013.06.009Search in Google Scholar

10. Report of the investigation of the catastrophic failure of a capacitor in the aft harmonic filter room on board RMS Queen Mary 2 while approaching Barcelona on 23 September 2010, Marine Accident Investigation Branch, December, 2011Search in Google Scholar

11. Tarasiuk T., Mindykowski J., An extended interpretation of THD concept in the wake of ship electric power system research, Measurement 45 (2012), 207-21210.1016/j.measurement.2011.02.016Search in Google Scholar

12. Tu Yong-Chang, Liu Jian-Gong, Wang Wei. Research on improved algorithm for harmonic current detection based on instantaneous reactive power theory [J]. Modern Electronics Technique, 2013, 36(3): 145-147Search in Google Scholar

13. Wang Yi-Fei, Li Yun-Wei. Three-Phase Cascaded Delayed Signal Cancellation PLL for Fast Selective Harmonic Detection [J]. IEEE Transactions on industrial electronics, 2013, 60(4): 1452-146310.1109/TIE.2011.2162715Search in Google Scholar

14. Xie Dong, Hui Jing. Application and research on modified ip-iq harmonic detection method [J]. Power Electronics, 2013, 47(1): 95-97Search in Google Scholar

15. Xu X, Mindykowski J., Chen P., Study on Hybrid Filtering Solution for Marine Electric Network, Polish Maritime Research 2 (65) 2010. vol.17, pp.72-7810.2478/v10012-010-0021-4Search in Google Scholar

16. Yang Sheng-Yue, Wu Min, Huang Shen-Xi. A harmonic current detection method considering frequency shift [J]. Automation of Electric Power Systems, 2012, 36(7): 57-61Search in Google Scholar

17. Yuan Xu-Feng, Cheng Shi-Jie, Wen Jin-Wu. An improved method of instantaneous symmetrical components and its detection for positive and negative sequence current [J]. Proceedings of the CSEE, 2008, 28(1): 52-58Search in Google Scholar

18. Zhou Qing, Mao Ya-Hui, Zhao Yong-Bin. Improved harmonic detection method without PLL and LPF [J]. Electrical Measurement & Instrumentation, 2012, 49(554): 27-31Search in Google Scholar

eISSN:
2083-7429
Sprache:
Englisch
Zeitrahmen der Veröffentlichung:
4 Hefte pro Jahr
Fachgebiete der Zeitschrift:
Technik, Einführungen und Gesamtdarstellungen, andere, Geowissenschaften, Atmosphärenkunde und Klimatologie, Biologie