Login
Registrieren
Passwort zurücksetzen
Veröffentlichen & Verteilen
Verlagslösungen
Vertriebslösungen
Themen
Allgemein
Altertumswissenschaften
Architektur und Design
Bibliotheks- und Informationswissenschaft, Buchwissenschaft
Biologie
Chemie
Geowissenschaften
Geschichte
Industrielle Chemie
Informatik
Jüdische Studien
Kulturwissenschaften
Kunst
Linguistik und Semiotik
Literaturwissenschaft
Materialwissenschaft
Mathematik
Medizin
Musik
Pharmazie
Philosophie
Physik
Rechtswissenschaften
Sozialwissenschaften
Sport und Freizeit
Technik
Theologie und Religion
Wirtschaftswissenschaften
Veröffentlichungen
Zeitschriften
Bücher
Konferenzberichte
Verlage
Blog
Kontakt
Suche
EUR
USD
GBP
Deutsch
English
Deutsch
Polski
Español
Français
Italiano
Warenkorb
Home
Zeitschriften
Geochronometria
Band 44 (2017): Heft 1 (January 2017)
Uneingeschränkter Zugang
Cathodoluminescence of synthetic zircon implanted by He
+
ion
Yuta Tsuchiya
Yuta Tsuchiya
,
Masahiro Kayama
Masahiro Kayama
,
Hirotsugu Nishido
Hirotsugu Nishido
und
Yousuke Noumi
Yousuke Noumi
| 01. Juni 2017
Geochronometria
Band 44 (2017): Heft 1 (January 2017)
Über diesen Artikel
Vorheriger Artikel
Nächster Artikel
Zusammenfassung
Artikel
Figuren und Tabellen
Referenzen
Autoren
Artikel in dieser Ausgabe
Vorschau
PDF
Zitieren
Teilen
Online veröffentlicht:
01. Juni 2017
Seitenbereich:
129 - 135
Eingereicht:
14. März 2016
Akzeptiert:
20. Jan. 2017
DOI:
https://doi.org/10.1515/geochr-2015-0054
Schlüsselwörter
cathodoluminescence
,
zircon
,
He ion implantation
,
radiation damage
,
metamict
© 2016 Y. Tsuchiya.
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.
Figure 1
CL spectrum of synthetic zircon (SZ) after total instrumental correction operated at 0.1 nA in a scanning mode.
Figure 2
Deconvolution of the CL spectra in energy units obtained from SZ by using a Gaussian curve fitting. Measured spectrum shown by a black solid line; deconvoluted components by broken lines of blue one in the blue region and orange one in the yellow region; sum of the components by the red dotted line.
Figure 3
Color CL images of unimplanted (top) and He+ ion-implanted (bottom) SZ samples at 2.14×10–3 C/cm2.
Figure 4
CL spectra of unimplanted and He+ ion-implanted SZ samples at 2.23×10–5 C/cm2 to 2.14×10–3 C/cm2.
Figure 5
Spectral deconvolution of the CL spectra in energy units obtained from implanted samples at (a) He+ ion-implanted at 2.23×10–5 C/cm2 and (b) at 2.14×10–3 C/cm2 by using a Gaussian curve fitting. Measured spectrum shown by a black solid line; deconvoluted components by broken lines of blue one in the blue region and orange one in the yellow region; sum of the components by the red dotted line.
Figure 6
Spectral deconvolution of the CL spectra in energy units from Malawi zircon by using a Gaussian curve fitting. Measured spectrum shown by a black solid line; deconvoluted components by broken lines of green one for REE activations and orange one in the yellow region; sum of the components by the red dotted line.
Figure 7