Temperature Stratification of Underfloor and Ceiling Based Air Heating Distribution System in an Experimental Room

Published Online: 21 May 2013
Volume & Issue: Volume 8 (2013) - Issue 1 (June 2013)
Page range: 43 - 50
Journal Details
License
Format
Journal
eISSN
1338-7278
ISSN
1338-7278
First Published
29 Mar 2013
Publication timeframe
2 times per year
Languages
English
Abstract

Most of air heating and ventilating systems for passive houses inlet air in floors. It is assumed that a natural motion of air is led upwards, and so the right stratification of temperature in the space is ensured. However, in the case of excellently insulated buildings it is possible to assume that an upper inlet of air is also able to ensure the required layering of temperature. Within the experiment an influence of upper and down air inlet for temperature stratification in the space was followed. Night sensors of indoor air temperature are placed for measurement purposes. Measurements are done in the long term. The results from measurements show that both, vertical and horizontal stratification of temperature in rooms of passive houses are equal regardless of the fact, which system of air inlet is used.

Keywords

[1] Sanytsky, M., Sekret, R., Wojcikiewicz, M. (2012) Energetic and ecological analysis of energy saving and passive houses, Selected Scientific Papers- Journal of Civil Engineering Vol.7, No. 1, pp. 71−78Search in Google Scholar

[2] Bielek, M., Bielek, B., Híreš, J., Szabó, J. (2012) The Annual Temperature Regime of Natural Physical Cavity and New Possibilities of it´s Energy Utilization, Selected Scientific Papers-Journal of Civil Engineering Vol. 7, No. 2, pp. 99 − 106Search in Google Scholar

[3] Stone,C., Bagoňa,M. (2013) Thermal responses of stabilized rammed earth for colder climatic regions, Advanced Materials Research Vol. 649 (2013), p. 171-174.Search in Google Scholar

[4] Sherman, M. H., Matson, M. E. (2001) Air Tightness in New U.S. Housing. Proc. 22nd AIVCConference, Air Infiltration and Ventilation Centre; LBNL-48671.Search in Google Scholar

[5] Al-Sanea, S. A., Zedan, M. F., Al-Harbi, M. B. (2012) Effect of supply Reynolds number and room aspect ratio on flow and ceiling heat-transfer coefficient for mixing ventilation, Int. Journal Therm. Sci. Vol. 54, 2012, p.176-187.Search in Google Scholar

[6] Al-Sanea, S. A., Zedan, M. F., Al-Harbi, M. B. (2012) Heat transfer characteristics in airconditioned rooms using mixing air-distribution system under mixed convection conditions, Int. Journal Therm. Sci. Vol. 59, p.247-259.10.1016/j.ijthermalsci.2012.04.023Search in Google Scholar

[7] Ho, S. H., Rosario, L., Rahman, M. M. (2011) Comparison of underfloor and overhead air distribution systems in an office environment, Buil. Env. Vol. 46, p.1415-1427.Search in Google Scholar

[8] Sekhar, R. Li, S. C., Melikov, A. K. (2011) Thermal comfort and indoor air quality in rooms with integrated personalized ventilation and under-floor air distribution systems. HVAC and RRes. Vol. 17, p.829-846.Search in Google Scholar

[9] Bauman, F. (2003) Under floor air distribution (UFAD) design guide. Atlanta: American Society of Heating, Refrigerating, and Air-Conditioning Engineers.Search in Google Scholar

[10] Bauman, F., Arens, E., Tanabe, S., Zhang, H., Baharlo A. (1995) Testing and optimizing the performance of a floor-based task conditioning system. Energy and Buildings. Vol. 22, p.73-186.10.1016/0378-7788(95)91161-JSearch in Google Scholar

[11] Kobayashi, N., Chen, Q. Y. (2003) Floor supply displacement ventilation in a small office. Indoor and Built Environment. Vol.12, p.281-291.10.1177/1420326X03035918Search in Google Scholar

[12] Chao, C. Y., Wan, M. P. (2004) Airflow and air temperature distribution in the occupied region of an under floor ventilation system. Building and Environment. Vol.39, p.749-762.10.1016/j.buildenv.2004.01.010Search in Google Scholar

[13] Lau, J., Chen, Q. Y. (2007) Floor-supply displacement ventilation for workshops. Building andEnvironment. Vol. 42, p.1718-1730.10.1016/j.buildenv.2006.01.016Search in Google Scholar

[14] Zhang, H., Huizenga, C., Arens, E., Yu, T. (2005) Modeling thermal comfort in stratified environments. In: Proceedings, Indoor Air 2005: 10th International Conference on Indoor Air Quality and Climate, 4.-9.10.2005 (p. 133-137). Beijing, China.Search in Google Scholar

[15] Cheong, K. W. D, Yu, W. J., Sekhar, S. C., Tham, K. W., Kosonen, R. (2007) Local thermal sensation and comfort study in a field environment chamber served by displacement ventilation system in the tropics. Building and Environment. Vol. 42, p.525-533.10.1016/j.buildenv.2005.09.008Search in Google Scholar

[16] Lopušniak, M. (2010) Comprehensive analysis of the shading structure for low energy house, Selected Sc. Papers: J of Civil Eng. Vol. 5, No. 1, pp. 57−68.Search in Google Scholar

Recommended articles from Trend MD

Plan your remote conference with Sciendo