[1. Hong-jun Liu, Pu Han, Dong-feng Wang.: Simulation of Boiler Drum Water Level System DMC-PID Cascade Control. Journal of System Simulation, 2004 (03): 450–453.]Search in Google Scholar
[2. Xiao Feng.: Fuzzy self-adapting PID control of drum water level in a power plant, IFAC Proceedings Volumes, Volume 40, Issue 8, 2007, pp. 77–83.10.3182/20070709-3-RO-4910.00011]Search in Google Scholar
[3. Nan-hua Yu, Wen-tong Ma, Ming Su.: Application of adaptive Grey predictor based algorithm to boiler drum level control, Energy Conversion and Management, Volume 47, Issue 18, 2006, pp 2999–3007.10.1016/j.enconman.2006.03.035]Search in Google Scholar
[4. Jing-tao Zhang, Wei Wang, Tian-you Chai, et al.: Intelligent Fuzzy Control of the Power Plant Boiler Water Level, IFAC Proceedings Volumes, Volume 32, Issue 2, 1999, pp. 7241–7246.10.1016/S1474-6670(17)57235-3]Search in Google Scholar
[5. Hamed Moradi, Majid Saffar-Avval, Firooz Bakhtiari-Nejad.: Sliding mode control of drum water level in an industrial boiler unit with time varying parameters: A comparison with – robust control approach, Journal of Process Control, Volume 22, Issue 10, 2012, pp. 1844–1855.10.1016/j.jprocont.2012.10.003]Search in Google Scholar
[6. Jing-qing Han.: Auto disturbance rejection control technique. Frontier Science, 2007, 1(1): 24–31.]Search in Google Scholar
[7. Hai-sheng Li.: Research on Parameter Tuning and Optimization of Active Disturbance Rejection Controller, Control Engineering. 2004,11(5): 419–423.]Search in Google Scholar
[8. Hong Chen, Jian Zeng, Guang-jun Wang.: Active Disturbance Rejection Control of Steam Generator Water Level Proceedings of the CSEE, 2010, (32): 103–107.]Search in Google Scholar
[9. 9. Ju-yuan Jiang, Li-jing Li.: The research on the new boiler water level automatic control system. Mechanic Automation and Control Engineering (MACE), 2011 Second International Conference on, 2011.10.1109/MACE.2011.5987312]Search in Google Scholar
[10. Jing-qing Han.: Auto disturbance rejection control technique. Beijing: National Defense Industry Press, 2009: 255-262,280-286 (in Chinese).]Search in Google Scholar
[11. Yong-chun Fang, Hui Shen, Xiu-yun Sun, Xu Zhang,Bin Xian.: Control of Active Disturbance Rejection Control of Unmanned Helicopter. Control Theory and Applications, 2014, 31(02): 238–243.]Search in Google Scholar
[12. Chang-mei Hu, Jun Ren.: Research and application of linear ADRC on cascade three-impulse control of drum water level. Electric Power, 2014, 47 (12): 28–31.]Search in Google Scholar
[13. Lin Fei, Hu Sun.: A new type of extended state observer with a measurement noise system. Control Theory and Applications. 2005, 22(6): 995–998]Search in Google Scholar
[14. Zhi-qiang Gao.: Scaling and bandwidth-parameterization based controller tuning Proceeding of the American Control Conference. United States: IEEE, 2003: 4989–4996.]Search in Google Scholar
[15. Simna Surendran, Vimal Kumar.: Neural Network Based PI Controller Parameter Calculation on a Boiler Drum Level System, Procedia Technology, Volume 24, 2016, pp. 1616–162210.1016/j.protcy.2016.05.164]Search in Google Scholar
[16. Hai-sheng Li.: Research on Parameter Tuning and Optimization of Active Disturbance Rejection Controller.Control Engineering. 2004, 11(5): 419–423.]Search in Google Scholar
[17. Jing-qing Han.: Active disturbance rejection controller and its application. Control and Decision, 1998, (01): 19–23.]Search in Google Scholar
[18. Yuan-qing Xia, Li Dai, Meng-yin Fu, et al.: Application of active disturbance rejection control in tank gun control system, Journal of the Franklin Institute, Volume 351, Issue 4, 2014, pp. 2299–2314.10.1016/j.jfranklin.2013.02.003]Search in Google Scholar
[19. Fei Xia, Hao Zhang, Gui Zhang, et al.: Image Processing in the Monitor of Boiler Drum Water Level on Power Plant, Energy Procedia, Volume 17, 2012, pp. 266–272.10.1016/j.egypro.2012.02.093]Search in Google Scholar
[20. Jing-qing Han.: Auto disturbance rejection control technique Frontier Science, 2007, 1(1): 24–31.]Search in Google Scholar
[21. Sun, K., L.P. Huang and Y. Mei.: A nonlinear auto-disturbance rejection control for matrix converter fed induction motor drive system. Transactions of China Electro technical Society 2007, 22(12), 39–45.]Search in Google Scholar
[22. Jing-qing Han, Wen-ge Zhang.: Active Disturbance Rejection Control for Large Delay Systems. Control and Decision, 1999, (04): 67–71.]Search in Google Scholar
[23. Xin Leng, Qi-dan Zhu.: Multi-model Predictive Control of Boiler Water Level for Marine Boiler Based on Radial Basis Function Neural Network Dynamic Compensation. Journal of Jilin University (Engineering and Technology Edition) 2011, 41(05): 1450–1455.]Search in Google Scholar
[24. Hang Yi, Luo ZW, Svinin M, et al.: Extended state observer technique for control of robot systems. The Proc. of the 4th IEEE World Congress on Intelligent Control and Automation. Shanghai, 2002.]Search in Google Scholar
[25. Y. Huang, H. Wan, J.L. Song, Analysis and Design for Third Order Nonlinear Continuous Extended Status Observer. Proceeding of 19th Chinese Control Congress. Hong Kong, China, 2000: 677–681.]Search in Google Scholar
[26. Min Xu, Shao-yuan Li, Wen-jian Cai, Cascade generalized predictive control strategy for boiler drum level, ISA Transactions, Volume 44, Issue 3, 2005, pp. 399–411.10.1016/S0019-0578(07)60212-2]Search in Google Scholar