1. bookVolume 63 (2021): Issue 1 (December 2021)
Journal Details
License
Format
Journal
eISSN
2784-1057
First Published
15 Dec 2012
Publication timeframe
1 time per year
Languages
English
access type Open Access

Geo-Electrical Method of Assessment of Coefficient of Permeability and Porosity of Soil of a Poultry Farmland

Published Online: 22 Dec 2021
Volume & Issue: Volume 63 (2021) - Issue 1 (December 2021)
Page range: 88 - 110
Received: 17 Jun 2021
Accepted: 22 Sep 2021
Journal Details
License
Format
Journal
eISSN
2784-1057
First Published
15 Dec 2012
Publication timeframe
1 time per year
Languages
English
Abstract

Leachate collected at the bottom of dead bird’s disposal pits may leak and migrate to pollute groundwater when soils and rocks present are porous. This study assessed the coefficient of permeability (K) and porosity (Ф) of soils and rocks in poultry farmland using 2 Dimensional (2D) electrical resistivity method and soil analysis. Geo-electrical data collection was achieved by using the dipole-dipole array. The field resistivity measurement was carried out along three traverse lines (three Profiles) of 100 m long which were oriented along with East-West directions. These measurements were taken in the order of increasing in offset distance interval of 5 m. The acquired apparent resistivity data were inverted using DIPPROWIN modeling software to perform 2D data inversion. Five soil samples from different locations at depths of 0 – 15 cm and 15 – 30 cm, on the poultry farmland, were collected, transported, and tested in the laboratory. K and Ф were determined using falling head and density methods respectively. The results obtained from the processed field resistivity data from the three profiles were presented as field data pseudo-sections, theoretical pseudo-section, and 2D resistivity structures. The 2D resistivity structure revealed three structures viz; highly conductive, slightly conductive, and resistive. The resistivity values of these structures ranged from 14.1-99.0 Ω m, 100-848 Ω m, and 1350-90330 Ω m respectively. The highly conductive structures were found in profiles 1 and 3 due to the downward migration of the contaminants from the dead bird disposal pit 1 and the feces disposal site through clayey sand soil. This occurs at the depth range of few meters from the surface to greater than 20 m. The presence of the slightly conductive structure is a result of filtration of the contaminants by the soil materials which increased the resistivity of the soil. The movement of the contaminant through the soil is an indication of the porous and permeable nature of the farmland. The resistive structure is only noticeable in profiles 1 and 2 but very prominent at the depth range of 5 m to more than 20 m and 5 m to 35 m along the profile length. The results of the analysis of the five soil samples from the poultry farmland showed a high value of 0.552 and 3.554 x 10−2cm/s of porosity (Ф) and coefficient of permeability (K) respectively. A strong correlation of R2 = 0.9878 existed between Ф and K. With these results geo-electrical method had successfully assessed Ф and K of the soil of the poultry farmland.

Keywords

[1] L.M Meyers, Impact of Poultry Mortality Pits on Groundwater Quality in Georgia. Proceedings of the United States Animal Health Association (1998) 555-562 Search in Google Scholar

[2] J.P. Greenhouse, and M. Monier-William, Geophysical Monitoring of groundwater contamination around waste disposal sites, Groundwater Monitoring Review. (1985)5 (4) 47-5910.1111/j.1745-6592.1985.tb00940.x Search in Google Scholar

[3] L.M. Abriola, Modeling contaminant transport in the subsurface: An interdisciplinary challenge, Rev. Geophys. (1987)25, 125 - 134.10.1029/RG025i002p00125 Search in Google Scholar

[4] J. Bear, (1972). Dynamics of Fluids in Porous Media Elsevier Inc., New York (1972) Search in Google Scholar

[5] S. Whitaker, Flow in Porous Media 1: A Theoretical Derivation of Darcy’s law, Transport Porous Med, (1986) 1, 3-2510.1007/BF01036523 Search in Google Scholar

[6] B.J. Christensen, T.O. Mason, and H.M. Jennings, Comparison of measured and calculated permeability for hardened cement pastes. Cement and Concrete Research (1996).26, (9), 1325-133410.1016/0008-8846(96)00130-5 Search in Google Scholar

[7] E. Huenges, and G. Zimmermann, Rock permeability and fluid pressure at the KTB. Oil & Gas Science and Technology – Rev. IFP (1999).54, (6), 689 – 69410.2516/ogst:1999058 Search in Google Scholar

[8] H. Sudo, T. Tanaka, T. Kobayashi, T. Kondo, T. Takahashi, M. Miyamoto, and M. Amagai, Permeability imaging in granitic rocks based on surface resistivity profiling. Exploration Geophysics (2004).35, 56 – 61.10.1071/EG04056 Search in Google Scholar

[9] H. Moo-Young, A. Johnson, D. Carson, C. Lew, S. Liu, and K. Hancook. Characterization of infiltration rates from landfills: Supporting groundwater modeling effort. Environmental Monitoring Assessment, (2004).96: 283 – 31110.1023/B:EMAS.0000031734.67778.d7 Search in Google Scholar

[10] P.F. Hudak, Groundwater monitoring strategies for variable versus constant contaminant loading functions. Environmental Monitoring Assessment (1998) 50: 271 – 28810.1023/A:1005806330741 Search in Google Scholar

[11] M.R. Stoline, R.N. Passerp, and J.R. Brooker, Clay barrier systems for waste disposal facilities, E and FN Spon, London, United Kingdom (1995). Search in Google Scholar

[12] G.J. Foose, C.H. Benson, andT.B. Edil Comparison of solute transport in three composite liners Journal of Geotechnical and Geoenvironmental Engineering. (2002). 128, 510.1061/(ASCE)1090-0241(2002)128:5(391) Search in Google Scholar

[13] M. Sophocleous, Interactions between groundwater and surface water: the state of the science. Hydrogeology Journal, (2002) 10(1) - 52-67.10.1007/s10040-001-0170-8 Search in Google Scholar

[14] D. Granato, and F. Smith. Electrical tomography monitoring of the excavation damaged zone of the gallery 04 in the Montterri rock laboratory: field experiments, modeling, and relationship with structural geology. Appl Clay Sci (1999)33: 21-3410.1016/j.clay.2006.03.008 Search in Google Scholar

[15] E.A. Ayolabi, and D.Y. Peter. Hydrochemical and electrical resistivity assessment of the impact of solid waste on groundwater at Oke Alfa refuses dumpsite, Lagos, Nigeria. Journal of science and engineering (2005)12 (1), 5936-5946 Search in Google Scholar

[16] A.A.R. Zohdy, Geoelectrical and Seismic refraction investigations near San Jose, California Groundwater, (1965)3 (3) 41-4810.1111/j.1745-6584.1965.tb01220.x Search in Google Scholar

[17] L.M. Page, The use of the geoelectric method for investigating geologic conditions in Santa Clara County California J. of Hydrology (1969).7 (2) 167-17710.1016/0022-1694(69)90054-7 Search in Google Scholar

[18] T. Meidav, An electrical resistivity survey for groundwater. Geophysics (1960). 25, (5), 1077 - 109310.1190/1.1438789 Search in Google Scholar

[19] A.A.R. Zohdy, Earth resistivity and seismic refraction in Clara County, California, Ph.D. thesis (unpublished), Stanford University, (1964). 131-135 Search in Google Scholar

[20] D.H. Griffiths, and R.D. Barker: Two dimension resistivity imaging and modeling of complex geology, Journal of Applied Geophysics. (1993). Vol, 211-22610.1016/0926-9851(93)90005-J Search in Google Scholar

[21] E. Aristodemou, and A. Thomas-Betts. A DC resistivity and induced polarization investigation at a waste disposal site and its environment, Journal of Applied Geophysics (2000). 275-30210.1016/S0926-9851(99)00022-1 Search in Google Scholar

[22] R. Guerin, M. L. Munoz, and A. Christopher, Leachate recirculation moisture content assessment by utilizing the geophysical technique, Waste Management (2004) 24: 785-79410.1016/j.wasman.2004.03.010 Search in Google Scholar

[23] E. Cardell, and M. Bernabini, Two case studies of the determination of parameter of urban waste dumps Journal of Applied Geophysics, (1997).167-17410.1016/S0926-9851(96)00056-0 Search in Google Scholar

[24] N.A. Gewande, D, R. Reinhart, P.A. Thomas, P.T. Mcreanor, Municipal solid waste in situ moisture content measurement using an electrical resistance sensor. Waste Management (2003).23: 667-67410.1016/S0956-053X(03)00100-4 Search in Google Scholar

[25] N. Abu-Zeid, and G. Santarato. On the correspondence between resistivity and texture of loose sediments, saturated with salt-water, Near Surf Geophys. (2004). 310.3997/1873-0604.2004012 Search in Google Scholar

[26] P.M. Soupios, M. Kouli, F. Vallianatos, A. Vafidis, and G. Stavroulakis, Estimation of aquifer hydraulic parameters from surficial geophysical methods: a case study of Kentis Basin in Chania (Crete- Greece). J. Hydrol. (2007). 338, 122-13110.1016/j.jhydrol.2007.02.028 Search in Google Scholar

[27] S. Chandra, S. Ahmed, A. Rann, and B. Dewandel, Estimation of hard rock aquifers hydraulic conductivity from geoelectrical measurements: a theoretical development with field application. J. Hydrol. (2008). 357, 218 – 22710.1016/j.jhydrol.2008.05.023 Search in Google Scholar

[28] O. de Lima, and S. Niwas, Estimation of hydraulic parameters of Shaly sandstone aquifers from geoelectrical measurements J. Hydrol. (2000). 235 (1-2), 12-2610.1016/S0022-1694(00)00256-0 Search in Google Scholar

[29] M. Loke, J. Chambers, D. Rucker, O. Kuras, and P. Wilkinson, P. Recent development in the direct-current geoelectrical imaging method. J. Appl. Geophys. (2013). 95. 135 – 156 Search in Google Scholar

[30] A. Samouelian, I. Cousin, A. Tabbagh, A. Bruand, and G. Richard, Electrical resistivity survey in soil science: a review. Soil Tillage Res. (2005). 83, 173-19310.1016/j.still.2004.10.004 Search in Google Scholar

[31] M.A. Rahaman, Review of basement Geology of South-western Nigeria, in Geology of Nigeria, edited by Kogbe C. A. 2nd revised edition Elizabethan Publ. Co. Lagos. (1976). 41 – 58. Search in Google Scholar

[32] N.K. Grant, A computation of radiometric ages from Nigeria Journal of Mining and Geology: (1970).6: 37 – 54. Search in Google Scholar

[33] M.H. Loke, The inversion of two-dimensional resistivity data. Unpublished. Ph.D. thesis, Uni. Of Birmingham. 1994. Search in Google Scholar

[34] D. H. Griffiths. J. Turnbull and A. L. Olayinka. Two-dimensional resistivity mapping with a computer-controlled array. First Break (1990). 8 121-129.10.3997/1365-2397.1990008 Search in Google Scholar

[35] W. M. Telford, L. P. Geldart, and R. E. Sheriff. Applied Geophysics, Cambridge University Press, U.K (1990).10.1017/CBO9781139167932 Search in Google Scholar

[36] M. H. Loke, Electrical Imaging Surveys for Environmental and Engineering Studies, a practical guide to 2-d and 3-d surveys. Penang, Malaysia. (2000). Search in Google Scholar

[37] P. Kearey, and M. Brooks. An Introduction to Geophysical Exploration, Blackwell Science Publications, U.S.A. (2002). Search in Google Scholar

[38] T. Dahlin, and B. Zhou. A numerical comparison of 2D resistivity imaging with 10 electrode arrays. Geophysical Prospecting. (2004) 52, 379-398.10.1111/j.1365-2478.2004.00423.x Search in Google Scholar

[39] M. H. Loke, and J. W. Lane. Inversion of data from electrical resistivity imaging surveys in water-covered areas. Exploration Geophysics. (2004) 35, 266-271.10.1071/EG04266 Search in Google Scholar

[40] M. H. Loke, 2D, and 3D Electric Imaging Surveys, Geo-tomo Software Sdn Bsd. Malaysia (2010). Search in Google Scholar

[41] M. H. Loke, L. Acworth, and T. Darlin, A comparison of smooth and blocky inversion methods in 2D electrical Imaging surveys, Geophysics, (2003) 35, 266-271,10.1071/EG03182 Search in Google Scholar

[42] C. Degroot-Hedlin and S. Constable. Occami’s inversion to generate smooth, two-dimensional models from magnetotelluric data. Geophysics (1990)35 (12). 1613-1624. Search in Google Scholar

[43] M. H. Loke, and R. D. Baker, Least-square deconvolution of apparent resistivity pseudo-sections. Geophysics. (1995) 60, 1682-1690.10.1190/1.1443900 Search in Google Scholar

[44] M. H. Loke, and R. D. Barker. Rapid least-squares inversion of apparent resistivity pseudo-sections by a quasi-Newton method. Geophysical Prospecting (1996) 44,(1) 133-152.10.1111/j.1365-2478.1996.tb00142.x Search in Google Scholar

[45] M. H. Loke, and R. D. Barker Practical techniques for 3D resistivity surveys and data inversion. Geophysical Prospecting. (1996) 44, 499-523.10.1111/j.1365-2478.1996.tb00162.x Search in Google Scholar

[46] P. Tsourlos, Modelling interpretation and inversion of multi-electrode resistivity survey data {DPhil Thesis], University of York, (1995) Search in Google Scholar

[47] R. Gopal, and A.S.R. Rao. Basic and applied soil mechanics 3rd edition New Age International publisher https://elementaryengineeringlibrary.com/civil-engineering/soil-mechanics/falling-head-variable-head-permeability-method. (2021) Search in Google Scholar

[48] X. Hao, B. C. Ball, J. L. B. Culley, M.R. Carter, and G.W. Parkin. Soil density and Porosity. Soil sampling and Methods of Analysis. CRC Press 2nd Edition Taylor and Francis Group. (2007) 745-752 Search in Google Scholar

[49] H. W. Olsen, “Hydraulic Flow-through Saturated Clays”, Proc. Ninth National Conference on Clays and Clay Minerals, (1962)131 - 161.10.1016/B978-1-4831-9842-2.50011-0 Search in Google Scholar

[50] J.E. Bowles, “Engineering Properties of Soils and Their Measurement”, McGraw Hill Book Co., New York (1970), Search in Google Scholar

Recommended articles from Trend MD

Plan your remote conference with Sciendo