Is there a correlation between the femoral anteversion angle and the elasticity of the hip muscles in cases of intoeing gait due to increased femoral anteversion angle?


Cite

Fig. 1

Definition of femoral anteversion angle measurement on axial CT. A is femoral neck horizontal angle. B is femoral condyles horizontal angle. A–B = femoral anteversion angle
Definition of femoral anteversion angle measurement on axial CT. A is femoral neck horizontal angle. B is femoral condyles horizontal angle. A–B = femoral anteversion angle

Fig. 2

SWE of a 5-year-old boy with femoral anteversion showing elasticity measurements of the adductor magnus (A), iliopsoas (B), gluteus medius (C), and gluteus maximus (D) muscles
SWE of a 5-year-old boy with femoral anteversion showing elasticity measurements of the adductor magnus (A), iliopsoas (B), gluteus medius (C), and gluteus maximus (D) muscles

Correlation of elasticity values and femoral anteversion angle measurements obtained by muscle elastography inter-observers with kappa statistics

Evaluated measurementInter-observer compliance values (κ)
Femoral anteversion angle0.913
Iliopsoas muscle elastographic elasticity value0.724
Adductor magnus muscle elastographic elasticity value0.711
Gluteus maximus muscle elastographic elasticity value0.674
Gluteus medius muscle elastographic elasticity value0.681

Bilateral iliopsoas, adductor magnus, gluteus maximus, gluteus medius muscles elasticity, and femoral anteversion values for both observers

Patient numberIliopsoas elasticityAdductor magnus elasticityGluteus maximus elasticityGluteus medius elasticityFemoral anteversion angle
RightLeftRightLeftRightLeftRightLeftRightLeft
O1O2O1O2O1O2O1O2O1O2O1O2O1O2O1O2O1O2O1O2
12.041.92.752.62.132.132.792.792.142.22.142.22.132.32.032.225242828
23.553.42.482.22.762.762.152.151.661.71.861.82.052.22.272.128292526
32.93.22.3722.992.992.762.761.561.61.511.52.292.11.751.526262422
41.722.452.22.022.022.812.811.521.61.531.52.312.51.481.521212928
52.082.63.843.62.232.233.713.711.381.41.451.41.931.81.671.820214441
61.7823.363.73.233.234.634.631.9221.721.71.7222.32.530324442
71.961.73.864.12.022.023.323.921.361.31.521.61.471.61.381.531333638
83.463.23.063.64.094.762.552.031.4721.461.41.381.41.831.521221615
92.52.92.482.12.772.142.732.211.41.61.41.41.841.71.591.737383637
102.662.23.193.91.651.212.232.981.1621.491.51.341.51.361.626253032
111.882.33.642.022.972.932.031.411.41.431.41.251.42.082.333323638
123.613.43.43.93.283.883.073.972.182.22.372.42.542.62.472.631333032
132.192.52.042.62.582.082.42.981.51.51.751.82.542.42.382.629272728
143.383.73.353.13.133.972.572.071.221.21.811.82.032.31.271.438363735
152.662.54.4442.082.984.784.081.631.61.492.21.351.51.211.430315451
162.3933.723.31.221.922.822.021.631.61.861.81.581.71.611.830323937
172.3521.321.82.82.082.352.951.981.92.22.31.6721.981.431322626
O1 – Observer 1; O2 – Observer 2

Correlation between elasticity values in muscle elastography examination and femoral anteversion angle measurements for each observer

Observer 1Observer 2
Correlation between FAA and iliopsoas muscle elasticity valuer: 0.562p <0.05r: 0.518p <0.05
Correlation between FAA and adductor magnus muscle elasticity valuer: 0.566p <0.01r: 0.522p <0.01
Correlation between FAA and gluteus maximus muscle elasticity valuer: –0.093p >0.05r: –0.014p >0.05
Correlation between FAA and gluteus medius muscle elasticity valuer: –0.259p >0.05r: –0.012p >0.05