Open Access

Influence of RC Element Wiring in Electrical Circuit on Electromechanical Thermostat Contact Wear


Cite

ALTHOUSE, A. D. – TURNQUIST, C. H. – BRACCIANO, A. F. 2004. Modern refrigeration and air conditioning. 18th ed. Tinley Park, IL : Goodheart-Wilcox Company Inc.Search in Google Scholar

BOŠANSKÝ, M. – VANYA, A. – HUDÁKOVÁ, M. – MALÝ, V. 2012. Tverdyje pokrytia kak vozmožnosť povyšenia nagruzočnoj sposobnosti vypuklo-vognytych zaceplenii vzaimodejstvujuščich s vio-masľanoj smaskoj. In Visnik nacionaľnovo techničnovo universitetu „XIII“ 2012. Charkiv : Nacionaľnyj techničeskij univesitet, 35, pp. 16–24.Search in Google Scholar

DANFOSS. 1998. Thermostats and pressure controls – Facts and functions. Nordborg : Danfoss A/S.Search in Google Scholar

DANFOSS. 2006. Table of vapour pressure for refrigerants used for charging 077B thermostats. Nordbord : Danfoss A/S.Search in Google Scholar

DANFOSS. 2012. Test of 077B thermostat. 9th ed. Nordborg : Danfoss A/S.Search in Google Scholar

IEC. 1999. EN/IEC 60730-1. Automatic electrical controls for household and similar use, Part 1: General requirements. Brussels : CENELEC.Search in Google Scholar

IEC. 2004. EN/IEC 60335-1 Household and similar electrical appliances – Safety, part 1: General requirements. Geneva : IEC.Search in Google Scholar

KEMET. 2015. Metallized Polypropylene Film EMI Suppression Capacitors. Retrieved from: www.kemet.com. Accessed 27 November 2015.Search in Google Scholar

KUČERA, M. – CHOTĚBORSKÝ, R. 2013. Analysis of the process of abrasive wear under experimental conditions. In Scientia agriculturae bohemica, 2013, no. 44, pp. 102–106.Search in Google Scholar

KRATZSHMAR, A. et al., 2010. Basic investigation on the behaviour of advanced Ag/SnO2 materials for contactor applications. Charleston (SC), IEEE, 2010, pp. 127–133.10.1109/HOLM.2010.5619553Search in Google Scholar

MÁCHAL, P. – TKÁČ, Z. – KOSIBA, J. – JABLONICKÝ, J. – HUJO, Ľ. – KUČERA, M. – TULÍK, J. 2013. Design of a laboratory hydraulic device for testing of hydraulic pumps. In Acta Universitatis Agriculturae et Silviculturae Mendelianae Brunensis., vol. 61, 2013, pp. 1313–1319.Search in Google Scholar

PANCON. 2015. Type Q/QRL Quencharc Capacitor. RC Snubber Network. Retrieved from: www.pancorp.com. Accessed 27 November 2015.Search in Google Scholar

UL. 2010. UL 873. Standard for temperature indicationg and regulating equipment. Chicago (IL) : UL Inc.Search in Google Scholar

eISSN:
1338-5267
Language:
English
Publication timeframe:
4 times per year
Journal Subjects:
Engineering, Introductions and Overviews, other