1. bookVolume 13 (2013): Issue 3 (June 2013)
Journal Details
License
Format
Journal
eISSN
1335-8871
First Published
07 Mar 2008
Publication timeframe
6 times per year
Languages
English
access type Open Access

Contactless Impedance Cardiography Using Embedded Sensors

Published Online: 21 Jun 2013
Volume & Issue: Volume 13 (2013) - Issue 3 (June 2013)
Page range: 157 - 164
Journal Details
License
Format
Journal
eISSN
1335-8871
First Published
07 Mar 2008
Publication timeframe
6 times per year
Languages
English

Impedance cardiography is a technique developed with the intent of monitoring cardiac output. By inspecting a few properties of the obtained signal (impedance cardiogram (ICG), the left ventricular ejection time can be derived with certainty, and an estimate of cardiac output is available. This signal is nowadays used in non-invasive monitoring, requiring the placement of electrodes over the subject’s skin, either ECG-type or in the form of encircling bands. The work here reported describes the implementation steps and the results obtained when embedding the ICG circuitry in a wheelchair’s backrest. The subject is seated normally, is normally dressed, and is completely unaware that monitoring is taking place. That means that the variation of tenths of ohm produced due to the cardiac cycle has to be detected with electrodes having substantial coupling impedance. Contactless ICG with embedded sensors was developed and tested on fourteen healthy subjects. The signal was always acquired, although respiratory activity is also important, constituting a noteworthy innovation in the area.

Keywords

[1] Martinsen, O.G., Grimnes, S. (2008). Bioimpedanceand Bioelectricity Basics (2nd ed.). Waltham, USA: Academic Press.Search in Google Scholar

[2] Ventura, H.O., Taler, S.J., Strobeck, J.E. (2005). Hypertension as a hemodynamic disease: The role of impedance cardiography in diagnostic, prognostic, and therapeutic decision making. American Journal ofHypertension, 18 (S2), 26S-43S.10.1016/j.amjhyper.2004.11.00215752931Search in Google Scholar

[3] Swanson, D., Webster, J. (1983). Errors in fourelectrode impedance plethysmography. Medical andBiological Engineering and Computing, 21 (6), 674-680.10.1007/BF024640296664128Search in Google Scholar

[4] Pallàs-Areny, R., Webster, J.G. (1993). Bioelectric impedance measurements using synchronous sampling. IEEE Transactions on BiomedicalEngineering, 40 (8), 824-829.10.1109/10.2384688258449Search in Google Scholar

[5] Patterson, R.P. (1989). Fundamentals of impedance cardiography. IEEE Engineering in Medicine andBiology Magazine, 8 (1), 35-38.10.1109/51.3240318238303Search in Google Scholar

[6] Luna-Lozano, P., Pallàs-Areny, R. (2009). Heart rate detection from impedance plethysmography based on concealed capacitive electrodes. In XIX IMEKO WorldCongress : Fundamental and Applied Metrology, 6-11 September 2009. IMEKO, 1701-1706.Search in Google Scholar

[7] Patterson, R.P. (2000). Bioelectric impedance measurements. In The Biomedical EngineeringHandbook (2nd ed.). Berlin, Germany: Springer.Search in Google Scholar

[8] Qu, M., Zhang, Y., Webster, J.G., Tompkins, W.J. (1986). Motion artifact from spot and band electrodes during impedance cardiography. IEEE Transactionson Biomedical Engineering, 33 (11), 1029-1036.10.1109/TBME.1986.3258693793123Search in Google Scholar

[9] Van De Water, J.M., Miller, T.W., Vogel, R.L., Mount, B.E., Dalton, M.L. (2003). Impedance cardiography: The next vital sign technology? Chest, 123 (6), 2028-2033.10.1378/chest.123.6.202812796185Search in Google Scholar

[10] Muller, M.D., Ryan, E.J., Kim, C.-H., Bellar, D.M., Blankfield, R.P., Glickman, E.L. (2010). Reliability of the measurement of stroke volume using impedance cardiography during acute cold exposure. Aviation,Space, and Environmental Medicine, 81 (2), 120-124.10.3357/ASEM.2604.2010Search in Google Scholar

[11] BIOPAC. Noninvasive cardiac output module -NICO100C. http://www.biopac.com/icg-impedancecardiography-noninvasive-cardiac-output-amplifier.Search in Google Scholar

[12] Woltjer, H.H., Bogaard, H.J., de Vries, P.M. (1997). The technique of impedance cardiography. EuropeanHeart Journal, 18 (9), 1396-1403.10.1093/oxfordjournals.eurheartj.a0154649458444Search in Google Scholar

[13] Kauppinen, P.K., Hyttinen, J.A., Malmivuo, J.A. (1998). Sensitivity distributions of impedance cardiography using band and spot electrodes analyzed by a three-dimensional computer model. Annals ofBiomedical Engineering, 26 (4), 694-702.10.1114/1.449662161Search in Google Scholar

[14] Valentinuzzi, M.E. (1996). Bioelectrical impedance techniques in medicine. Part I: Bioimpedance measurement. Critical Reviews in BiomedicalEngineering, 24 (4), 223-255.Search in Google Scholar

[15] medis. Medizinische Messtechnik GmbH. NiccomoApplications. www.niccomo.com/en/applicat.htmlSearch in Google Scholar

[16] Carter, B., Mancini, R. (2009). Op Amps for Everyone (3rd ed.). Elsevier.Search in Google Scholar

[17] Bertemes-Filho, P., Brown, B.H., Wilson, A.J. (2000). A comparison of modified Howland circuits as current generators with current mirror type circuits. Physiological Measurement, 21 (1), 1-6.10.1088/0967-3334/21/1/30110719993Search in Google Scholar

[18] Bertemes-Filho, P. (2002). Tissue characterisationusing an impedance spectroscopy probe. Doctoral dissertation, University of Sheffield, Sheffield, UK.Search in Google Scholar

[19] Rosell, J., Colominas, J., Riu, P., Pallàs-Areny, R., Webster, J.G. (1988). Skin impedance from 1 Hz to 1 MHz. IEEE Transactions on Biomedical Engineering, 35 (8), 649-651.10.1109/10.45993169817Search in Google Scholar

[20] Pinheiro, E.C., Postolache, O., Girão, P. (2010). Nonintrusive device for real-time circulatory system assessment with advanced signal processing capabilities. Measurement Science Review, 10 (5), 166-175.Search in Google Scholar

[21] Sankaralingam, S., Gupta, B. (2010). Determination of dielectric constant of fabric materials and their use as substrates for design and development of antennas for wearable applications. IEEE TransactionsInstrumentation and Measurement, 59 (12), 3122-3130.10.1109/TIM.2010.2063090Search in Google Scholar

Recommended articles from Trend MD

Plan your remote conference with Sciendo